AUTOSAR CP/AP Hybrid Architecture Design

This document details the hybrid communication architecture of AUTOSAR Classic Platform (CP) and Adaptive Platform (AP), including SOME/IP, DDS mapping, and Hypervisor isolation mechanisms.


💡 Field Insight from Michael Lin

Background: AUTOSAR AP + CP hybrid deployment on a domain controller

Key Challenges:

  • ASIL D safety functions and QM infotainment co-exist on the same SoC
  • SW/HW teams disagree on FFI (Freedom from Interference)
  • Hypervisor + MPU dual isolation approach disputed

My Solution:

  1. Led FFI verification plan, defining time/space isolation test cases
  2. Designed MPU region partitioning, mapping ASIL D/B/QM to separate memory regions
  3. Coordinated hypervisor vendor and silicon supplier for joint safety analysis
  4. Built inter-VM secure communication using VirtIO + shared memory

Quantified Results:

Metric Improvement
Architecture review pass rate First-pass
Architecture rework -30%
FFI test coverage 100%
Schedule risk Eliminated

Architecture Overview

CP vs AP Positioning

Feature Classic Platform (CP) Adaptive Platform (AP)
Target scenario Deeply embedded, real-time control High-performance compute, service architecture
OS OSEK/AUTOSAR OS POSIX-based (Linux, QNX)
Communication Signal-based Service-oriented
Scheduling Static, cyclic tasks Dynamic, event-driven
Update mechanism Fixed config Runtime config, OTA
Typical ECU Sensor/actuator nodes Domain controller, HPC
Safety level Up to ASIL D Typically up to ASIL B

CP/AP Hybrid Communication Architecture

Overall System Architecture

flowchart TB subgraph Vehicle["🚗 Vehicle Architecture"] direction TB subgraph HPC["🖥️ High-Performance Computing (HPC/Domain Controller)"] subgraph Hypervisor["Type-1 Hypervisor Layer"] direction LR subgraph VM_AP["VM1: Adaptive Platform"] direction TB subgraph AP_Apps["AP Applications"] AD["Autonomous Driving Apps"] DIAG["Diagnostics Services"] OTA["OTA Manager"] end subgraph AP_Services["AP Services (ara::)"] COM_AP["ara::com<br/>(SOME/IP + DDS)"] DIAG_AP["ara::diag"] UCM["ara::ucm"] PHM["ara::phm"] end subgraph AP_OS["POSIX OS"] LINUX["Linux / QNX"] end AP_Apps --> AP_Services --> AP_OS end subgraph VM_CP["VM2: Classic Platform (Safety)"] direction TB subgraph CP_SWC["CP SWCs"] CTRL["Control Algorithm SWC"] SAFETY["Safety Monitor SWC"] end subgraph CP_RTE["RTE Layer"] RTE["Runtime Environment"] end subgraph CP_BSW["BSW Layer"] COM_CP["COM Stack"] PDUR["PduR"] CANIF["CanIf"] end subgraph CP_MCAL["MCAL"] CAN_DRV["CAN Driver"] ETH_DRV["ETH Driver"] end CP_SWC --> CP_RTE --> CP_BSW --> CP_MCAL end subgraph VM_Safety["VM3: Safety Monitor"] SM["Safety Manager<br/>(ASIL D)"] end end end subgraph Network["🔌 In-Vehicle Network"] direction LR ETH["Automotive Ethernet<br/>(100BASE-T1/1000BASE-T1)"] CAN_FD["CAN FD Bus"] CAN_STD["CAN Bus"] end subgraph ECU_Zone["📦 Zone/Node ECUs"] direction LR subgraph Zone1["Zone ECU 1"] CP1["CP Stack"] end subgraph Zone2["Zone ECU 2"] CP2["CP Stack"] end subgraph Sensor["Sensor ECU"] SEN["Sensor Node"] end subgraph Actuator["Actuator ECU"] ACT["Actuator Node"] end end end VM_AP <-->|"Virtual Network"| VM_CP VM_AP <-->|"Health Monitoring"| VM_Safety VM_CP <-->|"Safety Status"| VM_Safety HPC <-->|"SOME/IP over Ethernet"| ETH ETH <--> Zone1 & Zone2 Zone1 <--> CAN_FD Zone2 <--> CAN_STD CAN_FD <--> Sensor CAN_STD <--> Actuator style HPC fill:#e3f2fd,stroke:#1976d2,stroke-width:2px style Hypervisor fill:#fff3e0,stroke:#f57c00 style VM_AP fill:#e8f5e9,stroke:#388e3c style VM_CP fill:#fff9c4,stroke:#f9a825 style VM_Safety fill:#ffcdd2,stroke:#c62828

SOME/IP Communication Mechanism

SOME/IP Stack Positioning

flowchart TB subgraph AP_Stack["Adaptive Platform"] direction TB APP_AP["Application Layer"] ARA_COM["ara::com API"] SOMEIP_AP["SOME/IP Binding"] UDP_TCP["UDP/TCP"] ETH_AP["Ethernet Driver"] APP_AP --> ARA_COM --> SOMEIP_AP --> UDP_TCP --> ETH_AP end subgraph CP_Stack["Classic Platform"] direction TB SWC["SWC Layer"] RTE["RTE"] SOMEIP_CP["SomeIpXf + SomeIpTp"] SOAD["SoAd (Socket Adaptor)"] TCPIP["TcpIp Stack"] ETHIF["EthIf"] ETH_CP["Eth Driver"] SWC --> RTE --> SOMEIP_CP --> SOAD --> TCPIP --> ETHIF --> ETH_CP end ETH_AP <-.->|"SOME/IP Messages"| ETH_CP style AP_Stack fill:#e8f5e9,stroke:#388e3c style CP_Stack fill:#fff9c4,stroke:#f9a825

SOME/IP Service Discovery Flow

sequenceDiagram participant Server as Service Provider<br/>(AP/CP) participant SD as SOME/IP-SD<br/>(Multicast) participant Client as Service Consumer<br/>(AP/CP) Note over Server,Client: Service discovery Server->>SD: OfferService (Multicast) SD-->>Client: OfferService Client->>SD: FindService (Multicast) SD-->>Server: FindService Server->>Client: OfferService (Unicast) Note over Server,Client: Subscription Client->>Server: SubscribeEventgroup Server->>Client: SubscribeEventgroupAck Note over Server,Client: Communication Client->>Server: Request (Method Call) Server->>Client: Response Server->>Client: Event Notification Server->>Client: Event Notification

SOME/IP Message Format

Field Size Description
Service ID 16 bit Service identifier
Method ID 16 bit Method/event identifier
Length 32 bit Message length
Client ID 16 bit Client identifier
Session ID 16 bit Session identifier
Protocol Version 8 bit Protocol version
Interface Version 8 bit Interface version
Message Type 8 bit Request/Response/Notification
Return Code 8 bit Return code
Payload Variable Serialized data

DDS Integration & Mapping

DDS Positioning in AP

flowchart TB subgraph AP_DDS["Adaptive Platform with DDS"] direction TB subgraph Apps["Applications"] AD_App["AD Planning"] Perception["Perception"] Fusion["Sensor Fusion"] end subgraph ARA["ara::com Layer"] PROXY["Service Proxy"] SKEL["Service Skeleton"] end subgraph Binding["Communication Binding"] direction LR SOMEIP_B["SOME/IP Binding"] DDS_B["DDS Binding"] end subgraph DDS_Stack["DDS Middleware"] direction TB DDS_API["DDS API (DCPS)"] RTPS["RTPS Protocol"] QOS["QoS Policies"] end subgraph Transport["Transport Layer"] UDP_M["UDP Multicast"] SHM["Shared Memory"] end Apps --> ARA --> Binding SOMEIP_B --> ETH_OUT["Ethernet"] DDS_B --> DDS_Stack --> Transport end style DDS_Stack fill:#e1f5fe,stroke:#0288d1 style Binding fill:#fff3e0,stroke:#f57c00

SOME/IP vs DDS

Feature SOME/IP DDS
Discovery SOME/IP-SD RTPS Discovery
Communication Request/Response, Pub/Sub Pub/Sub (data-centric)
QoS support Limited Rich (22+ QoS policies)
Serialization SOME/IP Serialization CDR (Common Data Representation)
Use cases SOA service calls High-rate data distribution
Typical usage Diagnostics, OTA, remote services Sensor data, point clouds, images
Real-time Medium High (configurable)

Key DDS QoS Policies

QoS Policy Description ADAS Example
Reliability Reliable/best effort Perception data: BEST_EFFORT
Durability Data persistence Map data: TRANSIENT_LOCAL
Deadline Update deadline Radar data: 50 ms
Liveliness Liveness detection Sensor health monitoring
History History depth Point cloud cache: KEEP_LAST(5)
Ownership Data ownership Primary/backup sensor switching

Hypervisor Isolation Mechanisms

Type-1 Hypervisor Architecture

flowchart TB subgraph Hardware["🔧 Hardware Platform"] CPU["Multi-core CPU<br/>(ARM/x86)"] MEM["Physical memory"] IO["I/O devices"] IOMMU["IOMMU/SMMU"] end subgraph Hypervisor["⚙️ Type-1 Hypervisor"] direction TB SCHED["Partitioning Scheduler"] MMU["Memory virtualization<br/>(Stage-2 Translation)"] VIRT_IO["I/O virtualization<br/>(Para-virtualization)"] HEALTH["Health Monitor"] end subgraph VMs["🖥️ VM Partitions"] direction LR subgraph VM1["VM1: Safety Critical"] OS1["AUTOSAR OS"] APP1["ASIL D SWC"] end subgraph VM2["VM2: Performance"] OS2["Linux"] APP2["AD Stack"] end subgraph VM3["VM3: Connectivity"] OS3["Linux"] APP3["Telematics"] end end Hardware --> Hypervisor --> VMs VM1 <-.->|"Virtual Network"| VM2 VM2 <-.->|"Virtual Network"| VM3 style VM1 fill:#ffcdd2,stroke:#c62828 style VM2 fill:#e8f5e9,stroke:#388e3c style VM3 fill:#e3f2fd,stroke:#1976d2 style Hypervisor fill:#fff3e0,stroke:#f57c00,stroke-width:2px

Isolation Layers

Isolation Layer Mechanism Function
Time isolation Partitioning scheduler Deterministic CPU time for each VM
Space isolation Stage-2 MMU Memory isolation between VMs
I/O isolation IOMMU/SMMU DMA access isolation
Interrupt isolation Virtual interrupt controller Interrupt routing isolation
Communication isolation Virtual network Controlled inter-VM communication

Inter-VM Communication

flowchart LR subgraph VM_A["VM A (AP)"] APP_A["Application"] VIRTIO_A["VirtIO Driver"] end subgraph Hypervisor["Hypervisor"] direction TB VSWITCH["Virtual Switch"] SHM["Shared Memory Region"] DOORBELL["Doorbell Interrupt"] end subgraph VM_B["VM B (CP)"] VIRTIO_B["VirtIO Driver"] APP_B["Application"] end APP_A --> VIRTIO_A VIRTIO_A -->|"1. Write Data"| SHM VIRTIO_A -->|"2. Notify"| DOORBELL DOORBELL -->|"3. Interrupt"| VIRTIO_B SHM -->|"4. Read Data"| VIRTIO_B VIRTIO_B --> APP_B VSWITCH -.->|"Manage"| SHM VSWITCH -.->|"Manage"| DOORBELL style Hypervisor fill:#fff3e0,stroke:#f57c00

MPU Memory Isolation (Spatial Isolation)

ASIL D and QM Coexistence

flowchart TB subgraph CPU_Core["CPU Core with MPU"] direction TB subgraph MPU["Memory Protection Unit"] REG["MPU Regions (8-16)"] end subgraph Memory_Map["Memory Layout"] direction TB subgraph ASIL_D_Region["🔴 ASIL D Region"] ASIL_CODE["ASIL D Code<br/>(R-X)"] ASIL_DATA["ASIL D Data<br/>(R-W)"] ASIL_STACK["ASIL D Stack<br/>(R-W)"] end subgraph ASIL_B_Region["🟡 ASIL B Region"] ASILB_CODE["ASIL B Code<br/>(R-X)"] ASILB_DATA["ASIL B Data<br/>(R-W)"] end subgraph QM_Region["🟢 QM Region"] QM_CODE["QM Code<br/>(R-X)"] QM_DATA["QM Data<br/>(R-W)"] QM_STACK["QM Stack<br/>(R-W)"] end subgraph Shared_Region["⚪ Shared Region"] SHARED["Exchange Buffer<br/>(Controlled Access)"] end end end MPU -->|"Protect"| Memory_Map style ASIL_D_Region fill:#ffcdd2,stroke:#c62828 style ASIL_B_Region fill:#fff9c4,stroke:#f9a825 style QM_Region fill:#c8e6c9,stroke:#388e3c style Shared_Region fill:#e0e0e0,stroke:#757575

MPU Configuration Table

MPU Region Start Address Size Attribute ASIL Access Notes
Region 0 0x0000_0000 4KB Code ASIL D R-X (Privileged) ASIL D boot code
Region 1 0x0000_1000 32KB Code ASIL D R-X ASIL D app code
Region 2 0x0000_9000 16KB Data ASIL D R-W (No Execute) ASIL D data
Region 3 0x0000_D000 4KB Stack ASIL D R-W (No Execute) ASIL D stack
Region 4 0x0001_0000 16KB Code ASIL B R-X ASIL B app code
Region 5 0x0001_4000 8KB Data ASIL B R-W (No Execute) ASIL B data
Region 6 0x0002_0000 64KB Code QM R-X QM app code
Region 7 0x0003_0000 32KB Data QM R-W (No Execute) QM data
Region 8 0x0004_0000 4KB Shared Mixed R-W (Controlled) Data exchange buffer
Region 9 0x0005_0000 8KB Peripheral - R-W (Device) Peripheral registers

Access Rights Matrix

Accessor Region ASIL D Code ASIL D Data ASIL B Code ASIL B Data QM Code QM Data Shared
ASIL D Task R-X R-W R R R R R-W
ASIL B Task - - R-X R-W R R R-W
QM Task - - - - R-X R-W R-W
ISR (ASIL D) R-X R-W R R R R R-W

Note: "-" means no access. MPU violations trigger exceptions.

Freedom from Interference (FFI) Implementation

flowchart TB subgraph FFI["Freedom from Interference"] direction TB subgraph Spatial["Spatial Isolation"] S1["MPU memory protection"] S2["Stack overflow detection"] S3["NULL pointer protection"] end subgraph Temporal["Temporal Isolation"] T1["Watchdog monitoring"] T2["Execution time monitoring"] T3["Scheduling protection"] end subgraph Communication["Communication Isolation"] C1["Data exchange validation"] C2["CRC checks"] C3["Sequence number checks"] end end subgraph Protection["Violation Handling"] P1["MPU exception"] P2["Watchdog reset"] P3["Error reporting"] end Spatial & Temporal & Communication --> Protection style Spatial fill:#ffcdd2,stroke:#c62828 style Temporal fill:#fff9c4,stroke:#f9a825 style Communication fill:#c8e6c9,stroke:#388e3c

ASIL Decomposition & Isolation Strategy

Isolation Strategy Implementation ISO 26262 Requirement
Same ASIL co-existence Software partition + MPU Part 6 requirement
Different ASIL co-existence MPU + FFI evidence ASIL decomposition evidence
ASIL D + QM Strict MPU isolation + diagnostics QM must not affect ASIL D
Multi-core allocation Core isolation + shared memory protection Multi-core safety manual

MPU Best Practices

Practice Recommendation Rationale
Least privilege Grant only necessary access Reduce fault propagation
No-write code region Prevent runtime code modification Prevent code injection
No-execute data Prevent data execution Prevent buffer attacks
Stack guard page Read-only guard page at stack base Detect stack overflow
Peripheral isolation Partition peripheral access by ASIL Prevent misoperation
Default deny Unconfigured regions have no access Catch illegal access

Summary: Hybrid Architecture Key Points

mindmap root((CP/AP Hybrid Architecture)) Communication SOME/IP Service discovery Method calls Event notification DDS High-rate data QoS policies Zero-copy CAN/CAN-FD Signal transport Real-time Isolation Hypervisor Time isolation Space isolation I/O isolation MPU ASIL/QM isolation FFI implementation Violation detection Safety ASIL D on CP ASIL B on AP Safety monitor VM

Last updated: 2026-01-25

ML
Verified

Michael Lin

MAGNA Quality Manager
Architect of Compliance-Wächter
AI for ISO 21434 & UN R155

作为 MAGNA 质量经理,我在德国汽车电子行业深耕 10+ 年。每天我都见证着一个新的瓶颈: 网络安全合规 (UN R155 / ISO 21434)

我正在构建 Compliance-Wächter — 一个 AI 驱动的 Copilot, 自动化 TARA 分析,将合规文书工作减少 70%